Sight Flow Indicator : |
|
|
|
 |
|
Full View Type |
|
|
|
|
|
Full View Sight Flow Indicators are assembled with tubular Borosilicate glass. These indicators |
|
|
are simple in construction and used for checking flow from any direction where various values |
|
|
or pump might have to be operated based on the flow in the line. These are recommended |
|
|
where there is no mechanical strain in the pipe line. Inside diameter of the glass tube is as |
|
|
large as or larger than the nominal size of the flow indicators. It is designed for only a |
|
|
negligible pressure drop. |
|
|
|
 |
 |
Flapper Type |
|
|
|
|
|
Flapper Type Sight Flow Indicators are recommended for horizontal and verical pipeline with |
|
|
upward flow. These units are best suited tranparent or slightly opaque solutions and are |
|
|
used for gases also. Position of the flapper indicates flow. One important use of these flow |
|
|
indicators is, in pipe lines where a downstream value may remain closed and even through |
|
|
the flow indicator remains full, there may not be any flow. In such cases, the flapper position |
|
|
alone can indicate where there is flow or not. |
|
|
|
 |
 |
Drip Type |
|
|
|
|
Drip Type Sight Flow Indicators are best adapted to vertical downward flow. These models |
|
|
are particularly useful in distillation and similar apparatus whereflow is apt to be |
|
|
intermittent. They are designed without any obstruction to handle the intermittent flow as |
|
|
|
|
|
|