Valve Manifolds : |
|
|
|
|
|
|
Features/Benefits |
|
|
|
|
|
Forged one piece body construction (no
|
- |
For High strength |
|
|
welding) |
|
|
|
|
Non Rotating Vee |
- |
which forms a bearing joint with the stem eliminates rotation between plug & seat at
|
|
|
|
|
closure. This prevents scoring and galling up the valve seat and ensure long life in |
|
|
|
|
repetitive shut off service. |
|
|
Safety Bonnet Lock |
- |
Prevents accidental disassembly.
|
|
|
Stem thread Rolled & Hard Plated |
- |
Provides additional strength & maximum service life.
|
|
|
Mirror Finish Stem, burnished to a 16RMS |
- |
Extends packing life and smoothens stem
operation. |
|
|
Adjustable Packing Below Stem threads |
- |
Prevents stem lubrication washout and isolates threads from process contamination.
|
|
|
Safety Back Seating |
- |
Provides secondary stem seal in full open position, prevents stem blowout. |
|
|
Stainless Steel Handle |
- |
For proper actuation. |
|
|
Body to Bonnet seal |
- |
Metal to Metal constant compression, Isolates bonnet threads from system fluids and
|
|
|
|
|
eliminates possible tensile. |
|
|
Dust Cap |
- |
Prevents contamination and lubricant washout out of bonnet assembly
|
|
|
|
VALVE MANIFOLDS |
|
|
|
Techno Flow range of Valve Manifolds offer a safe and economical method of installation to control and measure pressure of liquids and
|
|
|
gaseous media. They are ruggedly manufactured and precision machined to the most exacting dimensional tolerance to ensure perfect |
|
|
installation and application Valve Manifolds are functionally installed to control, measure , isolate , equalize , calibrate, drain, vent or |
|
|
differentiate the pressure of liquids and gases. |
|
|
|
Techno Flow Valve manifolds series offer 2, 3 and 5 valves configurations which come in remote mountingìRî Type ( Pipe to Pipe ), direct |
|
|
mounting ìTî & ìHî type(Pipe to Flange & Flange to Flange ) onto the instrument on
|
|
|
2-1/8î (54mm) centre. |
|
|
|
|
Pressure Rating:- |
|
|
|
Temp. |
C.S. |
S.S. |
Orifice |
Cv |
Room |
6000 PSI |
6000 PSI |
|
|
500°F |
4000 PSI |
4000 PSI |
4.8 mm |
0.52Max |
1000°F |
1500 PSI |
1500 PSI |
|
|
|
|
|
|
Manifold Selection:- |
|
|
|
Pressure and temperature rating are selected from ANSI B16.34 for class valve based on ANSI B16-Class 2500. Optional sour gas service
|
|
|
confirms to NACE STD MR-01-75. |
|
|
|
Testing:- |
|
|
|
Each valve is tested with nitrogen gas at 1000 psi for seat and packing leakage with a maximum allowable leack rate of 0.1 sec/min
|
|
|
Hydro test performanced with pure water at 1 and 1/2 times of working pressur. Other tests like vibration, temperatures, helium etc are |
|
|
available upon requests. |
|
|
|
|
Next |